Bki LGF-FC Uživatelský manuál

Procházejte online nebo si stáhněte Uživatelský manuál pro Zařízení Bki LGF-FC. BKI LGF-FC User Manual [en] Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk

Shrnutí obsahu

Strany 1 - Gas Pressure Fryer

Gas Pressure Fryer MODELS LGF, LGF-F, & LGF-FC Service Manual Serial Numbers 137733 and higher

Strany 2 - Warranty Information

Gas Pressure Fryer Introduction 8 Be Prepared for Emergencies Be prepared for fires, injuries, or other emergencies. Keep a first aid kit and

Strany 3 - Table of Contents

Gas Pressure Fryer Introduction 9 Safety Labels

Strany 4 - Introduction

Gas Pressure Fryer Introduction 10

Strany 5 - Specific Precautions

Gas Pressure Fryer Installation 11 Installation For installation information, refer to Gas Pressure Fryer, MODELS LGF, LGF-F, & LGF-FC, Inst

Strany 6 - Safe Work Practices

Gas Pressure Fryer Operation 12 Operation Controls and Indicators Refer to the figure and table below for an explanation of the fryer’s controls

Strany 7

Gas Pressure Fryer Operation 13 Item Description Function 1 Pressure Gauge Indicates the pressure inside the pot. 2 Spin Handle Used to tigh

Strany 8

Gas Pressure Fryer Operation 14 Item Description Function 8 A, B, C, D preset buttons These buttons are used to save and recall preset cycle an

Strany 9

Gas Pressure Fryer Operation 15 Care of the Shortening Solid shortening should always be returned to the filter vat while in the liquid state. If

Strany 10 - Do Not Smoke Near The Fryer

Gas Pressure Fryer Operation 16 The LGF/LGF-F fryer has a maximum temperature setting of 375º F (190º C). Do not use oil/shortening with a flash

Strany 11 - Safety Labels

Gas Pressure Fryer Operation 17 2. When frying chicken, connect the basket handle and lower the basket into the shortening in the fryer pot.

Strany 12

Warranty Information LIMITED ONE YEAR WARRANTY BKI (The "Company") warrants to the original purchaser that at time of shipment from the Com

Strany 13 - Installation

Gas Pressure Fryer Operation 18 LGF-FC Operation System Programming Use the following figure and table to set options that apply to each product

Strany 14 - Operation

Gas Pressure Fryer Operation 19 Table 1. System Programming Procedure STEP ACTION DISPLAY COMMENTS 1 Press the FILTER/OFF/FRY switch to FRY. L

Strany 15

Gas Pressure Fryer Operation 20 Product Programming Use the following figure and table to set a maximum of eight product programs. The product pr

Strany 16

Gas Pressure Fryer Operation 21 Table 2. Product Programming Procedure STEP ACTION DISPLAY COMMENTS 1 Press the FILTER/OFF/FRY switch to FRY.

Strany 17 - LGF and LGF-F Operation

Gas Pressure Fryer Operation 22 STEP ACTION DISPLAY COMMENTS 13 Repeat steps 5-12 when programming stages 2, 3, 4 and 5 for Electric and Gas a

Strany 18 - Cooking (LGF and LGF-F)

Gas Pressure Fryer Operation 23 Start-Up (LGF-FC) 1. Make sure the main drain valve is closed. 2. Fill pot with shortening to about one inch

Strany 19

Gas Pressure Fryer Operation 24 4. Carefully drop the chicken in the shortening one piece at a time starting with thighs and drumsticks. The fry

Strany 20 - LGF-FC Operation

Gas Pressure Fryer Operation 25 Recipes Fried Onion Rings 1. Take frozen onion rings from freezer or bread fresh onion rings with Imperial brea

Strany 21

Gas Pressure Fryer Operation 26 Whole Turkey (12 to 14 pounds) 1. Rinse and bread turkey with Imperial breading. 2. Place turkey into fryer bas

Strany 22 - Product Programming

Gas Pressure Fryer Operation 27 Operation After Gas or Power Outage The fryer may shut off automatically if the gas supply is interrupted or the

Strany 23

Gas Pressure Fryer Table of Contents 1 Table of Contents Table of Contents ...

Strany 24

Gas Pressure Fryer Maintenance 28 Maintenance For maintenance information, refer to Gas Pressure Fryer, MODELS LGF, LGF-F, & LGF-FC, Installa

Strany 25 - Cooking (LGF-FC)

Gas Pressure Fryer Replacement Parts 29 Replacement Parts Use the information in this section to identify replacement parts. To order replacement

Strany 26

Gas Pressure Fryer Replacement Parts 30 Figure 3. Lid/Arm Assembly, AN3211350S (Sheet 1 of 4)

Strany 27 - Recipes

Gas Pressure Fryer Replacement Parts 31 Figure 3. Lid/Arm Assembly, AN3211350S (Sheet 2 of 4)

Strany 28

Gas Pressure Fryer Replacement Parts 32 Figure 3. Lid/Arm Assembly, AN3211350S (Sheet 3 of 4)

Strany 29 - Normal Shutoff

Gas Pressure Fryer Replacement Parts 33 Figure 3. Lid/Arm Assembly, AN3211350S (Sheet 4 of 4)

Strany 30 - Maintenance

Gas Pressure Fryer Replacement Parts 34 Table 3. Lid/Arm Assembly (AN3211350S) Parts ITEM # PART # QTY DESCRIPTION Figure 3 (sheet 1) AN3211

Strany 31 - Replacement Parts

Gas Pressure Fryer Replacement Parts 35 Figure 4. Dead Weight & Pressure Gauge Assembly Table 4. Dead Weight & Pressure Gauge Assembly

Strany 32

Gas Pressure Fryer Replacement Parts 36 Figure 5. Drain/Motor/Piping Assembly

Strany 33

Gas Pressure Fryer Replacement Parts 37 Table 5. Drain/Motor/Piping Assembly Parts ITEM # PART # QTY DESCRIPTION 1 TU0205 2 TUBING, 12&q

Strany 34

Gas Pressure Fryer Introduction 2 Introduction The LGF Pressure Fryer is compact, attractive and functional in design. It is constructed of a sta

Strany 35

Gas Pressure Fryer Replacement Parts 38 Figure 6. Burner Tray Assembly

Strany 36 - SB3491S

Gas Pressure Fryer Replacement Parts 39 Table 6. Burner Tray Assembly Parts ITEM # PART # QTY DESCRIPTION SB3467 1 LP GAS BURNER TRAY ASSEM

Strany 37

Gas Pressure Fryer Replacement Parts 40 Figure 7. Control/Insulation Panel LGF & LGF-F

Strany 38

Gas Pressure Fryer Replacement Parts 41 Table 7. Control/Insulation Panel LGF & LGF-F Parts ITEM # PART # QTY DESCRIPTION 1 B1050 1 B

Strany 39

Gas Pressure Fryer Replacement Parts 42 Figure 8. Control/Insulation Panel LGF -FC

Strany 40

Gas Pressure Fryer Replacement Parts 43 Table 8. Control/Insulation Panel LGF -FC Parts ITEM # PART # QTY DESCRIPTION 1 CP0039 1 CONTROL

Strany 41

Gas Pressure Fryer Replacement Parts 44 Figure 9. Door Assembly W/Pocket (SB3290) Table 9. Door Assembly W/Pocket (SB3290) Parts ITEM # PART

Strany 42

Gas Pressure Fryer Replacement Parts 45 Figure 10. Oil Vat Assembly (AN32112800)

Strany 43

Gas Pressure Fryer Replacement Parts 46 Table 10. Oil Vat Assembly (AN32112800) Parts ITEM # PART # QTY DESCRIPTION AN86208400 1 FILTER S

Strany 44

Gas Pressure Fryer Replacement Parts 47 Figure 12. Solenoid Valve Assembly Table 12. Solenoid Valve Assembly Parts ITEM # PART # QTY DESCR

Strany 45

Gas Pressure Fryer Introduction 3 Specific Precautions Lids for LGF Pressure Fryers manufactured prior to May 27, 1980 (or units with serial num

Strany 46

Gas Pressure Fryer Replacement Parts 48 Figure 13. Quick Disconnect Assembly (SB1997S) Table 13. Quick Disconnect Assembly (SB1997S) Parts IT

Strany 47

Gas Pressure Fryer Replacement Parts 49 Figure 14. Drain Valve & Plugs (SB1999S) Table 14. Drain Valve & Plugs (SB1999S) Parts ITEM #

Strany 48

Gas Pressure Fryer Replacement Parts 50 Accessories Description Accessory # Figure # Item # BASKET, LGF B0108B Figure 15 1 HANDLE, TEE S

Strany 49

Gas Pressure Fryer Replacement Parts 51 Components Description Component # Figure # Item # ARM ADJUSTABLE STOP /FKM A0101 Figure 16 1 CA

Strany 50

Gas Pressure Fryer Wiring Diagrams 52 Wiring Diagrams Refer to the table below to find the wiring diagram associated with your unit. Wiring Diag

Strany 51

Gas Pressure Fryer Wiring Diagrams 53 Figure 17. LGF-F 120V/60HZ/1 Phase

Strany 52 - Accessories

Gas Pressure Fryer Wiring Diagrams 54 Figure 18. LGF-FC 120V/60HZ/1 Phase

Strany 53 - Components

Gas Pressure Fryer Wiring Diagrams 55 Figure 19. LGF-FC 220V/50HZ/1 Phase

Strany 54 - Wiring Diagrams

Gas Pressure Fryer Wiring Diagrams 56 Figure 20. LGF-FC 220V/60HZ/1 Phase

Strany 55

Gas Pressure Fryer Wiring Diagrams 57 Figure 21. LGF-FC 240V/50HZ/1 Phase

Strany 56

Gas Pressure Fryer Introduction 4 Safe Work Practices Do Not Store Or Use Anything Flammable Near The Fryer Your pressure fryer is powered by

Strany 57

P.O. Box 80400, Simpsonville, S.C. 29680-0400, USA http://www.bkideas.com Made and printed i

Strany 58

Gas Pressure Fryer Introduction 5 Keep The Floor Around Your Fryer Clean Of Shortening Make sure to keep the floor around your fryer clean of s

Strany 59

Gas Pressure Fryer Introduction 6 Always Make Sure The Lid Hook Is Latched When Closing The Fryer To make sure the lid hook is latched properly

Strany 60

Gas Pressure Fryer Introduction 7 Keep Away From The Vent Hot steam escapes from the vent continuously when you are using your fryer. You could

Příbuzné modely LGF | LGF-F |

Komentáře k této Příručce